Documentation

Docs / User guide

Troubleshooting and files#

A model doesn't mesh#

  1. Run Geometry › Check Geometry... and fix what it lists, worst first. Imported geometry often needs Heal... (Checking and healing).
  2. Look for very thin or tiny features compared with the rest of the model (sub-micron gaps in a millimetre model, slivers left by booleans). Remove them, or merge faces with Heal.
  3. Partly overlapping objects at the same mesh priority are allowed, but check that the right object wins: Check Model lists them (Overlapping objects).

A solve fails or stops#

  • Check Model first. It catches missing ports, faces with two boundaries, ports that don't touch a conductor, and setups without frequencies.
  • Read Results › Logfile. The last lines usually say what went wrong. A failed run's files are kept in logs/<setup>/failed-run/ in the results folder.
  • Out of memory: lower Maximum unknowns or the element order, coarsen mesh rules, use symmetry planes, or solve on a cluster or in the cloud.
  • The linear solver doesn't converge: usually a model problem (a floating conductor, a port shorted by metal, a lumped port across a zero-size gap). Check the ports first.

Results look wrong#

Symptom Likely cause
S-parameters still change a lot between passes Not converged: lower Maximum ΔS per pass, raise Maximum refinements (see Convergence)
A small model converges in one or two passes but disagrees with measurements Electrically small: set Minimum passes to 3 or more, and a lower ΔS target
|S11| or |S21| above 0 dB A lossless model with a coarse mesh; or ports referenced to the wrong impedance
Strong mode conversion on a symmetric differential pair Mesh asymmetry: refine the pair with Max Element Size on Faces
Radiating model shows too much loss or reflection at the boundary The absorbing boundary is too close: give it at least λ/4 (λ/2 for far fields)
Far field doesn't match the port's accepted power Fields saved only at the solution frequency: check the far-field frequency
Wave port reports the wrong impedance The port face is too small, cuts through a field region, or the ground conductors aren't ticked

Where TE10 keeps things#

What Where
The project <name>.te10 (JSON)
Its results <name>.te10results/ beside it (layout)
The app's log (crashes, errors) Linux: ~/.local/share/TE10/TE10 Studio/logs/te10studio.log; Windows: %LOCALAPPDATA%\TE10\TE10 Studio\logs\te10studio.log
Cluster settings Your user settings; share them as .te10cluster files (sharing)
AWS key for cloud solves The te10 profile in ~/.aws, readable only by you
TE10's SSH key (if you chose key login) ~/.ssh/te10_ed25519

Environment variables#

Variable Effect
TE10_PALACE_BIN The palace program to use instead of TE10's own
TE10_MPIRUN_BIN The mpirun that goes with it
TE10_CLUSTER_PROFILES A shared folder of .te10cluster files for your organisation

Getting help#

When you report a problem, include the version (Help › About TE10 Studio...), what you did, and the log file above. For a failed solve, the logs/<setup>/ folder of the project's results says the most.

Report a problem or send feedback#

Choose Help > Report a Problem or Help > Send Feedback. Nothing is sent until you click Send, and Show Exactly What Will Be Sent displays the full report first. Project files are never attached. The recent app log is attached only if you tick its box, and it can include project and file names.

If the app hits an unexpected error, the error window offers Report This Problem.

Anonymous diagnostics#

Diagnostics are off unless you turn them on at first launch or in Help > Privacy and Diagnostics. They send the app version, OS type, command counts, solve success or failure, and crash locations in TE10 code. They never send projects, geometry, results, file names, paths, error text, license keys, or computer names. To keep them off for a whole computer or managed install, set the environment variable TE10_NO_TELEMETRY=1.