Documentation

Docs / User guide

EMI and radiated emissions#

TE10 Studio can help you predict and debug radiated emissions before you go to a test lab. It solves the fields from your board, cable or enclosure, and gives you the electric field at a chosen distance.

Pre-compliance only

TE10 Studio doesn't certify a product against CISPR, FCC or any other regulation. A simulation can't replace a test at an accredited lab. TE10's emission workflow hasn't yet been compared with chamber measurements, so use it to rank designs and find problems, and check your own correlation against a measured product.

What's built in and what isn't#

Task In TE10 Studio
Import boards, enclosures and existing EM projects Yes, see Importing models
Full-wave solve with open (radiating) boundaries Yes
Far-field pattern, radiated power, peak direction Yes
Surface currents and field plots to find the radiator Yes
Field strength at 3 m or 10 m in dBµV/m With the script below
Scaling to your real source spectrum With the script below
Regulatory limit lines No. Enter the limit from the current edition of your standard
Quasi-peak, average or RBW receiver detectors No
Antenna height scan and turntable No. Sweep the far-field directions instead
Reflecting ground plane of a test site Not modeled by the script. See Accuracy limits
Conducted emissions (LISN) No built-in workflow

Workflow#

  1. Bring in the geometry. Import the board, plus anything that radiates with it: enclosure, heatsink, attached cable and return path. A cable left out of the model can't radiate in the result.
  2. Add the noise source. Put a lumped port where the noise enters, such as across a driver output or a switching node. Use a resistance close to the source's impedance.
  3. Make the space open. Add an air box with an absorbing boundary. See Ports and boundaries.
  4. Add a far-field setup. Use Far Field... in the Monitors group, covering the full sphere so the script can find the worst direction.
  5. Sweep the band you care about. Include the source's harmonics. Save far-field data at each frequency you want to evaluate.
  6. Convert to field strength with the script below and compare it with your limit.
  7. Find the radiator. Use Surface Current..., field plots and the 3D pattern, change the design, then solve again.

Field strength at a test distance#

TE10 stores the far field as r·E in volts (peak). In free space, at distance d, the RMS field is:

E_rms = |r·E| / (√2 · d) · √(P_source / P_incident)
dBµV/m = 20 · log10(E_rms · 1e6)

P_incident is the power TE10 used to drive the port. P_source is your source's available power. For a source with an open-circuit RMS voltage V_oc and resistance R, P_source = V_oc² / (4R).

Run this with te10 run emissions.py, or from Tools › Run Script...:

import numpy as np
import te10_studio.api as em

PROJECT = "board.te10"
SETUP = "S1"
DISTANCE_M = 3.0
FREQ_GHZ = 0.3
V_OC_RMS = 0.1     # noise source, open-circuit RMS volts at this frequency
R_SOURCE = 50.0    # ohms
LIMIT_DBUV_M = 40.0  # enter the limit from your standard

prj = em.Project.open(PROJECT)
result = prj.setups[SETUP].solve(cores=4)
pattern = result.farfield().pattern(FREQ_GHZ)

p_source = V_OC_RMS ** 2 / (4 * R_SOURCE)
scale = np.sqrt(p_source / pattern.p_inc)
e_rms = pattern.values("rE") / (np.sqrt(2) * DISTANCE_M) * scale
db = 20 * np.log10(np.maximum(e_rms, 1e-30) * 1e6)
i = int(np.argmax(db))

print(f"{pattern.freq_ghz:.4f} GHz: {db[i]:.1f} dBuV/m at {DISTANCE_M:g} m")
print(f"Worst direction: theta={pattern.theta[i]:.0f}, phi={pattern.phi[i]:.0f}")
print(f"Margin to limit: {LIMIT_DBUV_M - db[i]:.1f} dB")

pattern(...) uses the nearest solved frequency, so check the printed frequency.

We checked this formula on a solved half-wave dipole: for 0.401 W radiated and 2.26 dBi directivity it gives 123.5 dBµV/m at 3 m, matching the textbook E_rms = √(30·P·D) / d.

Several sources#

Each driven port is its own excitation. Sources at the same frequency add as complex fields, so a true sum needs their relative phase. If the phases are unknown, an RSS sum gives a typical value, and adding magnitudes gives a worst case.

Accuracy limits#

  • Ground reflections. Many test sites have a reflecting floor. The formula is free space, and a reflection can raise the received field by up to about 6 dB.
  • Distance. The formula is valid only in the far field. At the low end of the band, 3 m may not be far enough from a large product.
  • Low frequency. An absorbing boundary needs distance from the model, and a wavelength at 30 MHz is 10 m. Solve again with a larger air box and check that the answer holds.
  • Source accuracy. The result can only be as good as your noise spectrum. Use a measured or circuit-simulated source.
  • Detectors. Limits use quasi-peak, peak or average detectors. A steady sine maps directly, while pulsed or broadband noise doesn't.
  • Missing structure. Cables, connectors and enclosure seams often dominate emissions and must be in the model.

For design decisions, compare before and after on the same model. Relative changes are usually more reliable than an absolute prediction.