Validation
Palace, extended and tested
TE10 Studio uses the open-source Palace solver with added features. This page shows what we changed, how each part works, and how it compares with analytic answers, published methods, and independent models.
Starting point
Palace, plus what we changed
TE10 Studio is built on Palace, the Apache-2.0 finite element solver created by AWS. Palace supplies the core solver. We carry 25 patches on top of it: 10 are open pull requests from the Palace project, and the rest are our additions and build changes. Patched files are marked, and source and notices are available.
| Solver change | Origin | Tested against |
|---|---|---|
| Conductor roughness | TE10 | Published curves, closed forms, equivalent boundaries |
| Terminal S-parameters | TE10 | Independent PEC and PMC half models |
| Multi-mode wave ports | TE10 | Half models, power balance, reciprocity |
| Lossy wave ports | TE10 | Matched and shorted lines with known answers |
| Low-frequency port fixes and DC point | TE10 | Analytic coaxial line |
| Incident plane wave | TE10 | Mie series for PEC and dielectric spheres |
| Wideband dielectric dispersion | TE10 | Djordjevic-Sarkar formula tests |
| Reduced adaptive sweep with voltage paths | TE10 | Full postprocessing, identical S and port impedance |
| Exact voltage-path line integrals | Palace PR 1049 | That pull request's own tests |
| Wave-port fix on adapted parallel meshes | Palace PR 1056 | That pull request's own tests and our reproduction |
Added to Palace
Conductor surface roughness
Palace models a conductor with a surface impedance. We added Huray, Hammerstad, and Groisse roughness to that boundary. The test model is a 25 mm stripline from 1 to 40 GHz, with copper trace and ground planes.
How it works
- A frequency-dependent complex factor K(ω) multiplies the conductor's surface impedance.
- Huray uses Bracken's causal form, so roughness changes both loss and reactance.
- The same factor is used by driven solves, eigenmode solves, the wave-port mode solve, and the adaptive sweep.
Huray: insertion loss (dB)
Data table
| GHz | Simulated | First-order prediction | Smooth copper |
|---|---|---|---|
| 1 | 0.085 | 0.088 | 0.074 |
| 2 | 0.144 | 0.148 | 0.116 |
| 5 | 0.301 | 0.309 | 0.215 |
| 10 | 0.534 | 0.545 | 0.352 |
| 15 | 0.752 | 0.765 | 0.482 |
| 20 | 0.953 | 0.968 | 0.600 |
| 25 | 1.148 | 1.165 | 0.718 |
| 30 | 1.333 | 1.351 | 0.830 |
| 35 | 1.514 | 1.533 | 0.941 |
| 40 | 1.690 | 1.710 | 1.050 |
Hammerstad: insertion loss (dB)
Data table
| GHz | Simulated | First-order prediction | Smooth copper |
|---|---|---|---|
| 1 | 0.085 | 0.085 | 0.074 |
| 2 | 0.143 | 0.145 | 0.116 |
| 5 | 0.295 | 0.297 | 0.215 |
| 10 | 0.495 | 0.499 | 0.352 |
| 15 | 0.671 | 0.675 | 0.482 |
| 20 | 0.827 | 0.832 | 0.600 |
| 25 | 0.978 | 0.983 | 0.718 |
| 30 | 1.120 | 1.125 | 0.830 |
| 35 | 1.258 | 1.263 | 0.941 |
| 40 | 1.393 | 1.397 | 1.050 |
Groisse: insertion loss (dB)
Data table
| GHz | Simulated | First-order prediction | Smooth copper |
|---|---|---|---|
| 1 | 0.092 | 0.093 | 0.074 |
| 2 | 0.157 | 0.159 | 0.116 |
| 5 | 0.307 | 0.310 | 0.215 |
| 10 | 0.502 | 0.505 | 0.352 |
| 15 | 0.674 | 0.678 | 0.482 |
| 20 | 0.829 | 0.833 | 0.600 |
| 25 | 0.978 | 0.983 | 0.718 |
| 30 | 1.119 | 1.124 | 0.830 |
| 35 | 1.257 | 1.261 | 0.941 |
| 40 | 1.391 | 1.396 | 1.050 |
Huray: loss factor K
Data table
| GHz | Extracted from solve | Closed form |
|---|---|---|
| 1 | 1.196 | 1.244 |
| 2 | 1.355 | 1.408 |
| 5 | 1.677 | 1.735 |
| 10 | 2.002 | 2.062 |
| 15 | 2.215 | 2.275 |
| 20 | 2.372 | 2.431 |
| 25 | 2.494 | 2.553 |
| 30 | 2.595 | 2.652 |
| 35 | 2.679 | 2.735 |
| 40 | 2.752 | 2.805 |
Insertion loss of the 25 mm line (dB)
| Copper | 1 GHz | 5 GHz | 10 GHz | 20 GHz | 40 GHz |
|---|---|---|---|---|---|
| Smooth copper | 0.074 | 0.215 | 0.352 | 0.600 | 1.050 |
| Huray, simulated / predicted | 0.085 / 0.088 | 0.301 / 0.309 | 0.534 / 0.545 | 0.953 / 0.968 | 1.690 / 1.710 |
| Hammerstad, simulated / predicted | 0.085 / 0.085 | 0.295 / 0.297 | 0.495 / 0.499 | 0.827 / 0.832 | 1.393 / 1.397 |
| Groisse, simulated / predicted | 0.092 / 0.093 | 0.307 / 0.310 | 0.502 / 0.505 | 0.829 / 0.833 | 1.391 / 1.396 |
Checks
| Check | Reference | Result |
|---|---|---|
| Roughness factor | Bracken, DesignCon 2012, and closed-form limits | 14 of 14 checks pass |
| K = 2 implementation | Equivalent smooth conductor with σ/4 | Max |ΔS| 1.7e-10 |
| Complex K | Equivalent explicit surface impedance | Max |ΔS| 1.6e-11 at 1 GHz, 6.2e-12 at 10 GHz |
| Adaptive sweep | Uniform solves at the same frequencies | Max |ΔS| 9e-6 |
Added loss is 3-8% below the first-order prediction for Huray and 1.4-5% below for Hammerstad and Groisse from 5 to 40 GHz. At 1 GHz, where the added loss is only about 0.011 dB, the Huray difference reaches 19%. The prediction assumes conductor loss scales linearly with surface resistance, which is only approximate near trace edges.
Added to Palace
Terminal wave ports
Coupled traces need terminal S-parameters, such as differential and common-mode results. We test them on a symmetric coupled microstrip with a width step, with and without loss, against separate half models that use none of the terminal code.
How it works
- Palace solves the port's modes on one shared port face, and each mode gets its own S-parameter row.
- After the solve, TE10 converts the modal S-matrix to terminal S-parameters using each mode's voltage on the terminal paths.
- Terminal combinations are never excited in the solve, and de-embedding stays modal, using each mode's own propagation constant.
- Terminal currents come from the method that tested most accurate for each frequency range, with a smooth blend between.
Lossy case: substrate tan δ = 0.02 and copper traces.
Differential reflection, SDD11 (dB)
Data table
| GHz | TE10 terminal ports | Odd-mode half model |
|---|---|---|
| 2 | -9.987 | -10.162 |
| 4 | -11.657 | -11.747 |
| 6 | -18.669 | -18.261 |
| 8 | -13.253 | -13.058 |
| 10 | -9.718 | -9.776 |
Differential transmission, SDD21 (dB)
Data table
| GHz | TE10 terminal ports | Odd-mode half model |
|---|---|---|
| 2 | -0.599 | -0.579 |
| 4 | -0.556 | -0.548 |
| 6 | -0.443 | -0.447 |
| 8 | -0.754 | -0.762 |
| 10 | -1.182 | -1.173 |
Common-mode reflection, SCC11 (dB)
Data table
| GHz | TE10 terminal ports | Even-mode half model |
|---|---|---|
| 2 | -28.745 | -29.498 |
| 4 | -10.342 | -10.377 |
| 6 | -6.372 | -6.316 |
| 8 | -12.321 | -12.155 |
| 10 | -41.904 | -41.088 |
Common-mode transmission, SCC21 (dB)
Data table
| GHz | TE10 terminal ports | Even-mode half model |
|---|---|---|
| 2 | -0.149 | -0.148 |
| 4 | -0.713 | -0.709 |
| 6 | -1.660 | -1.675 |
| 8 | -0.926 | -0.936 |
| 10 | -0.759 | -0.757 |
Largest difference from the half models, 2-10 GHz
| Result | Lossless, magnitude and phase | Lossless max |ΔS| | Lossy, magnitude and phase | Lossy max |ΔS| |
|---|---|---|---|---|
| SDD11 | 0.409 dB, 0.40° | 0.0065 | 0.408 dB, 0.53° | 0.0063 |
| SDD21 | 0.020 dB, 0.42° | 0.0069 | 0.021 dB, 0.42° | 0.0065 |
| SCC11 | 5.230 dB, 103.91° | 0.0062 | 0.817 dB, 25.43° | 0.0058 |
| SCC21 | 0.018 dB, 0.77° | 0.0134 | 0.016 dB, 0.77° | 0.0123 |
The large SCC11 dB and phase differences occur at 10 GHz, in a deep reflection null: -54.7 dB against -49.4 dB lossless and -41.9 dB against -41.1 dB lossy. The absolute error there is small, and max |ΔS| is the better measure. Reciprocity error is at most 8.73e-09. Differential-to-common conversion, which should vanish by symmetry, is at most 8.99e-04. Solved on the current solver build.
Added to Palace
Multi-mode wave ports
Palace's standard wave port carries one mode per port face. Coupled lines need both even and odd modes on the same face.
How it works
- Several modes share one port face, each with its own S-parameter index.
- The port boundary correction is generalized from one mode to K modes, and reduces to the original single-mode terms when K = 1.
- The modes on a face come from one shared eigensolve, so modes with equal propagation constants stay distinct.
| Check | Reference | Result |
|---|---|---|
| Symmetric step, reflections | PEC and PMC half models | Within 0.4 dB and 0.8° |
| Symmetric step, transmissions | PEC and PMC half models | Within 0.015 dB and 0.7° |
| Step on one trace, power | Lossless power balance | Within 1.3e-4 |
| Reciprocity | |S - Sᵀ| | Below 3e-9 |
| Adaptive sweep | Uniform solves | Within 2e-9 |
Added to Palace
Lossy wave ports
On lossy lines the propagation constant is complex. Using only its real part mismatches the port by the line's loss angle.
How it works
- The port boundary, mode forms, and reactions use the complex propagation constant.
- Modes are normalized to a unit unconjugated reaction, and S is the unconjugated projection onto each mode.
- Lossless ports are unchanged.
| Check | Reference | Before | After |
|---|---|---|---|
| Matched lossy coax, 1 MHz | |S11| near 0 | 1.37 | 3.6e-3 |
| Shorted lossy guide | |S11| = e-2αL | - | Within 5e-7 |
| Lossless port | Unchanged | - | |ΔS| 1e-12 |
Added to Palace
Low-frequency accuracy and the DC point
Below about 1 GHz, conductor loss changes the port modes. We fixed the mode search and coaxial port calculation, then added a DC point to sweeps that start at 0 Hz.
How it works
- Wave-port modes are searched by eigenvalue magnitude, so conductor loss at MHz doesn't select a spurious mode.
- Coaxial lumped ports take ln(b/a) from an integral over the meshed face.
- The DC point solves five low frequencies and fits S with Re S even and Im S odd in frequency, which keeps S(0) real.
| Check | Reference | Result |
|---|---|---|
| Conductor R′ from wave port, 1 MHz-3 GHz | Surface impedance | Within 1% |
| Shorted coax through lumped port | Passivity and mesh convergence | Passive; halving the mesh cuts spurious Re Zin 8× |
| DC point, PEC coax | Exact DC | |ΔS11| 2.7e-5 |
| DC point, copper with thickness | Exact DC | |ΔS11| 2.3e-6 |
| DC point, solid conductor | Exact DC | |ΔS11| 2.5e-4 |
Added to Palace
Incident plane wave and RCS
We added an incident plane-wave excitation for scattering problems and checked radar cross section against the exact Mie series.
How it works
- The incident field enters through a first-order absorbing boundary in a total-field formulation.
- Far-field output is the scattered field.
| Sphere | Monostatic error | Forward error | Note |
|---|---|---|---|
| PEC | +0.51 dB | +0.24 dB | Worst bistatic angle 0.83 dB |
| Dielectric | -0.74 dB | +0.12 dB | 5.5 dB error inside a -36 dBsm null |
The empty-domain incident field error is 0.9%. These errors are limited by the first-order absorbing boundary.
In the app
How other results are calculated
These tools run on solved results in the app rather than inside Palace.
| Feature | How TE10 does it | Check and result |
|---|---|---|
| RLGC from S-parameters | S to Y to the chain matrix; phase is followed per eigenmode across frequency | Coaxial line within the 1% test limit of closed-form L, C, Z0 |
| SPICE export | Vector fit with several orders; each is checked for gain from DC to 100× fmax and at infinity; passivity correction keeps the constant term | Analytic lossy line in ngspice: max |S| error 1.2e-4, transient 7e-4 V |
| Causality check | Windowed time-domain response | Automated tests |
| Eye diagrams | S21 to step response by FFT, then a PRBS7 bit pattern | Eye height +0.01%, -0.41%, +0.34%, +1.06% against exact RC and skin-effect channels |
| Quantum EPR | Junction as a lumped inductive port in eigenmode, then circuit diagonalization | Exact circuit agrees to printed digits; order-3 model within 1.4% (qubit), 0.6% (resonator) of refined Palace runs |
| Symmetry planes | Solve half the model and scale cut port impedances | |S21| within 0.007 dB, phase 0.05° of the whole model |
| Far field | Palace near-to-far-field output | Half-wave dipole 2.26 dBi, theory about 2.2 dBi |
| Waveguide | Standard wave ports | WR-90 test limits: |S11| below -40 dB, |S21| within 0.01 dB, phase within 0.5° |
| Cloud job sizing | Before launch: machine, hourly rate, your time limit, and hard cost cap. The model-based estimate appears after the job starts | Run on AWS at 8, 48, and 96 cores |
| Adapted-mesh reuse | Reuses a whole mesh when the model's hash matches | Automated tests |
Read before relying on it
Known limits
These are the places where the current evidence stops or where results differ.
- Most checks use analytic answers, symmetry, or independent TE10 models. They aren't measurements of fabricated hardware.
- Wave ports solve down to 100 kHz. Lumped ports were tested to 10 kHz.
- Conductors are modeled as surfaces. DC resistance and internal inductance are correct for flat traces, but can be up to 2× high on round or single-surface conductors.
- Roughness uses Huray, Hammerstad, and Groisse forms. Other roughness models are approximated on import.
- Plane-wave accuracy is limited by the first-order absorbing boundary, especially in deep RCS nulls.
- Results depend on the model, mesh, settings, and software version. Validate critical designs against measurements.
Test it on your own models
The best comparison is one you run yourself. Join the beta and compare against the references you trust.