Validation

Palace, extended and tested

TE10 Studio uses the open-source Palace solver with added features. This page shows what we changed, how each part works, and how it compares with analytic answers, published methods, and independent models.

Palaceopen-source solver at the core, with our changes applied as separate patches
14 of 14roughness factor checks against published and closed-form values
0.013largest terminal-port |ΔS| against independent half models
29 of 29TE10 solver benchmarks passed

Starting point

Palace, plus what we changed

TE10 Studio is built on Palace, the Apache-2.0 finite element solver created by AWS. Palace supplies the core solver. We carry 25 patches on top of it: 10 are open pull requests from the Palace project, and the rest are our additions and build changes. Patched files are marked, and source and notices are available.

Solver changeOriginTested against
Conductor roughnessTE10Published curves, closed forms, equivalent boundaries
Terminal S-parametersTE10Independent PEC and PMC half models
Multi-mode wave portsTE10Half models, power balance, reciprocity
Lossy wave portsTE10Matched and shorted lines with known answers
Low-frequency port fixes and DC pointTE10Analytic coaxial line
Incident plane waveTE10Mie series for PEC and dielectric spheres
Wideband dielectric dispersionTE10Djordjevic-Sarkar formula tests
Reduced adaptive sweep with voltage pathsTE10Full postprocessing, identical S and port impedance
Exact voltage-path line integralsPalace PR 1049That pull request's own tests
Wave-port fix on adapted parallel meshesPalace PR 1056That pull request's own tests and our reproduction

Added to Palace

Conductor surface roughness

Palace models a conductor with a surface impedance. We added Huray, Hammerstad, and Groisse roughness to that boundary. The test model is a 25 mm stripline from 1 to 40 GHz, with copper trace and ground planes.

How it works

  • A frequency-dependent complex factor K(ω) multiplies the conductor's surface impedance.
  • Huray uses Bracken's causal form, so roughness changes both loss and reactance.
  • The same factor is used by driven solves, eigenmode solves, the wave-port mode solve, and the adaptive sweep.

Huray: insertion loss (dB)

SimulatedFirst-order predictionSmooth copper
0.000.501.001.502.00010203040Frequency (GHz)
Data table
GHzSimulatedFirst-order predictionSmooth copper
10.0850.0880.074
20.1440.1480.116
50.3010.3090.215
100.5340.5450.352
150.7520.7650.482
200.9530.9680.600
251.1481.1650.718
301.3331.3510.830
351.5141.5330.941
401.6901.7101.050

Hammerstad: insertion loss (dB)

SimulatedFirst-order predictionSmooth copper
0.000.501.001.50010203040Frequency (GHz)
Data table
GHzSimulatedFirst-order predictionSmooth copper
10.0850.0850.074
20.1430.1450.116
50.2950.2970.215
100.4950.4990.352
150.6710.6750.482
200.8270.8320.600
250.9780.9830.718
301.1201.1250.830
351.2581.2630.941
401.3931.3971.050

Groisse: insertion loss (dB)

SimulatedFirst-order predictionSmooth copper
0.000.501.001.50010203040Frequency (GHz)
Data table
GHzSimulatedFirst-order predictionSmooth copper
10.0920.0930.074
20.1570.1590.116
50.3070.3100.215
100.5020.5050.352
150.6740.6780.482
200.8290.8330.600
250.9780.9830.718
301.1191.1240.830
351.2571.2610.941
401.3911.3961.050

Huray: loss factor K

Extracted from solveClosed form
1.001.502.002.503.00010203040Frequency (GHz)
Data table
GHzExtracted from solveClosed form
11.1961.244
21.3551.408
51.6771.735
102.0022.062
152.2152.275
202.3722.431
252.4942.553
302.5952.652
352.6792.735
402.7522.805

Insertion loss of the 25 mm line (dB)

Copper1 GHz5 GHz10 GHz20 GHz40 GHz
Smooth copper0.0740.2150.3520.6001.050
Huray, simulated / predicted0.085 / 0.0880.301 / 0.3090.534 / 0.5450.953 / 0.9681.690 / 1.710
Hammerstad, simulated / predicted0.085 / 0.0850.295 / 0.2970.495 / 0.4990.827 / 0.8321.393 / 1.397
Groisse, simulated / predicted0.092 / 0.0930.307 / 0.3100.502 / 0.5050.829 / 0.8331.391 / 1.396

Checks

CheckReferenceResult
Roughness factorBracken, DesignCon 2012, and closed-form limits14 of 14 checks pass
K = 2 implementationEquivalent smooth conductor with σ/4Max |ΔS| 1.7e-10
Complex KEquivalent explicit surface impedanceMax |ΔS| 1.6e-11 at 1 GHz, 6.2e-12 at 10 GHz
Adaptive sweepUniform solves at the same frequenciesMax |ΔS| 9e-6

Added loss is 3-8% below the first-order prediction for Huray and 1.4-5% below for Hammerstad and Groisse from 5 to 40 GHz. At 1 GHz, where the added loss is only about 0.011 dB, the Huray difference reaches 19%. The prediction assumes conductor loss scales linearly with surface resistance, which is only approximate near trace edges.

Added to Palace

Terminal wave ports

Coupled traces need terminal S-parameters, such as differential and common-mode results. We test them on a symmetric coupled microstrip with a width step, with and without loss, against separate half models that use none of the terminal code.

How it works

  • Palace solves the port's modes on one shared port face, and each mode gets its own S-parameter row.
  • After the solve, TE10 converts the modal S-matrix to terminal S-parameters using each mode's voltage on the terminal paths.
  • Terminal combinations are never excited in the solve, and de-embedding stays modal, using each mode's own propagation constant.
  • Terminal currents come from the method that tested most accurate for each frequency range, with a smooth blend between.

Lossy case: substrate tan δ = 0.02 and copper traces.

Differential reflection, SDD11 (dB)

TE10 terminal portsOdd-mode half model
-20-15-10-5246810Frequency (GHz)
Data table
GHzTE10 terminal portsOdd-mode half model
2-9.987-10.162
4-11.657-11.747
6-18.669-18.261
8-13.253-13.058
10-9.718-9.776

Differential transmission, SDD21 (dB)

TE10 terminal portsOdd-mode half model
-1.25-1.00-0.75-0.50-0.25246810Frequency (GHz)
Data table
GHzTE10 terminal portsOdd-mode half model
2-0.599-0.579
4-0.556-0.548
6-0.443-0.447
8-0.754-0.762
10-1.182-1.173

Common-mode reflection, SCC11 (dB)

TE10 terminal portsEven-mode half model
-50-40-30-20-100246810Frequency (GHz)
Data table
GHzTE10 terminal portsEven-mode half model
2-28.745-29.498
4-10.342-10.377
6-6.372-6.316
8-12.321-12.155
10-41.904-41.088

Common-mode transmission, SCC21 (dB)

TE10 terminal portsEven-mode half model
-2.00-1.50-1.00-0.500.00246810Frequency (GHz)
Data table
GHzTE10 terminal portsEven-mode half model
2-0.149-0.148
4-0.713-0.709
6-1.660-1.675
8-0.926-0.936
10-0.759-0.757

Largest difference from the half models, 2-10 GHz

ResultLossless, magnitude and phaseLossless max |ΔS|Lossy, magnitude and phaseLossy max |ΔS|
SDD110.409 dB, 0.40°0.00650.408 dB, 0.53°0.0063
SDD210.020 dB, 0.42°0.00690.021 dB, 0.42°0.0065
SCC115.230 dB, 103.91°0.00620.817 dB, 25.43°0.0058
SCC210.018 dB, 0.77°0.01340.016 dB, 0.77°0.0123

The large SCC11 dB and phase differences occur at 10 GHz, in a deep reflection null: -54.7 dB against -49.4 dB lossless and -41.9 dB against -41.1 dB lossy. The absolute error there is small, and max |ΔS| is the better measure. Reciprocity error is at most 8.73e-09. Differential-to-common conversion, which should vanish by symmetry, is at most 8.99e-04. Solved on the current solver build.

Added to Palace

Multi-mode wave ports

Palace's standard wave port carries one mode per port face. Coupled lines need both even and odd modes on the same face.

How it works

  • Several modes share one port face, each with its own S-parameter index.
  • The port boundary correction is generalized from one mode to K modes, and reduces to the original single-mode terms when K = 1.
  • The modes on a face come from one shared eigensolve, so modes with equal propagation constants stay distinct.
CheckReferenceResult
Symmetric step, reflectionsPEC and PMC half modelsWithin 0.4 dB and 0.8°
Symmetric step, transmissionsPEC and PMC half modelsWithin 0.015 dB and 0.7°
Step on one trace, powerLossless power balanceWithin 1.3e-4
Reciprocity|S - Sᵀ|Below 3e-9
Adaptive sweepUniform solvesWithin 2e-9

Added to Palace

Lossy wave ports

On lossy lines the propagation constant is complex. Using only its real part mismatches the port by the line's loss angle.

How it works

  • The port boundary, mode forms, and reactions use the complex propagation constant.
  • Modes are normalized to a unit unconjugated reaction, and S is the unconjugated projection onto each mode.
  • Lossless ports are unchanged.
CheckReferenceBeforeAfter
Matched lossy coax, 1 MHz|S11| near 01.373.6e-3
Shorted lossy guide|S11| = e-2αL-Within 5e-7
Lossless portUnchanged-|ΔS| 1e-12

Added to Palace

Low-frequency accuracy and the DC point

Below about 1 GHz, conductor loss changes the port modes. We fixed the mode search and coaxial port calculation, then added a DC point to sweeps that start at 0 Hz.

How it works

  • Wave-port modes are searched by eigenvalue magnitude, so conductor loss at MHz doesn't select a spurious mode.
  • Coaxial lumped ports take ln(b/a) from an integral over the meshed face.
  • The DC point solves five low frequencies and fits S with Re S even and Im S odd in frequency, which keeps S(0) real.
CheckReferenceResult
Conductor R′ from wave port, 1 MHz-3 GHzSurface impedanceWithin 1%
Shorted coax through lumped portPassivity and mesh convergencePassive; halving the mesh cuts spurious Re Zin 8×
DC point, PEC coaxExact DC|ΔS11| 2.7e-5
DC point, copper with thicknessExact DC|ΔS11| 2.3e-6
DC point, solid conductorExact DC|ΔS11| 2.5e-4

Added to Palace

Incident plane wave and RCS

We added an incident plane-wave excitation for scattering problems and checked radar cross section against the exact Mie series.

How it works

  • The incident field enters through a first-order absorbing boundary in a total-field formulation.
  • Far-field output is the scattered field.
SphereMonostatic errorForward errorNote
PEC+0.51 dB+0.24 dBWorst bistatic angle 0.83 dB
Dielectric-0.74 dB+0.12 dB5.5 dB error inside a -36 dBsm null

The empty-domain incident field error is 0.9%. These errors are limited by the first-order absorbing boundary.

In the app

How other results are calculated

These tools run on solved results in the app rather than inside Palace.

FeatureHow TE10 does itCheck and result
RLGC from S-parametersS to Y to the chain matrix; phase is followed per eigenmode across frequencyCoaxial line within the 1% test limit of closed-form L, C, Z0
SPICE exportVector fit with several orders; each is checked for gain from DC to 100× fmax and at infinity; passivity correction keeps the constant termAnalytic lossy line in ngspice: max |S| error 1.2e-4, transient 7e-4 V
Causality checkWindowed time-domain responseAutomated tests
Eye diagramsS21 to step response by FFT, then a PRBS7 bit patternEye height +0.01%, -0.41%, +0.34%, +1.06% against exact RC and skin-effect channels
Quantum EPRJunction as a lumped inductive port in eigenmode, then circuit diagonalizationExact circuit agrees to printed digits; order-3 model within 1.4% (qubit), 0.6% (resonator) of refined Palace runs
Symmetry planesSolve half the model and scale cut port impedances|S21| within 0.007 dB, phase 0.05° of the whole model
Far fieldPalace near-to-far-field outputHalf-wave dipole 2.26 dBi, theory about 2.2 dBi
WaveguideStandard wave portsWR-90 test limits: |S11| below -40 dB, |S21| within 0.01 dB, phase within 0.5°
Cloud job sizingBefore launch: machine, hourly rate, your time limit, and hard cost cap. The model-based estimate appears after the job startsRun on AWS at 8, 48, and 96 cores
Adapted-mesh reuseReuses a whole mesh when the model's hash matchesAutomated tests

Read before relying on it

Known limits

These are the places where the current evidence stops or where results differ.

Test it on your own models

The best comparison is one you run yourself. Join the beta and compare against the references you trust.

Request beta access