Coming from Q3D#

TE10 Studio can open a Q3D Extractor design and solve it as a full-wave driven model. It doesn't reproduce Q3D's quasi-static solver, so expect some differences, especially at higher frequencies. This page explains them.

Importing a Q3D design#

Choose Import Ansys Electronics Desktop Project... and select the .aedt or .aedtz file.

In Q3D In TE10 Studio
Geometry, variables and materials Imported
Signal nets with sources and sinks A 50 Ω lumped port at each source and sink on non-return nets
Ground net The return conductor
Only signal nets The signal net with the largest conductor surface becomes the return
Thin Conductor A finite-conductivity sheet with that material and thickness
Open region An air box with an absorbing boundary, padded by twice the model's largest size
Solve setup A driven S-parameter solve

A port needs a flat, axis-aligned source or sink face with part of the return conductor beside it in the same plane, as at the end of a microstrip. TE10 reports any it can't convert, and you can draw those ports yourself.

Some projects store geometry as native binary Parasolid, which TE10 can't read. Export that geometry as STEP and use Import STEP / CAD File... instead.

Getting R, L, G, C#

You want Use Notes
Per-metre R, L, G, C vs frequency Export ▾ › RLGC in the S-parameter window Needs a uniform line with a port at each end of each conductor
Static L and C matrices, Z₀ and delay RLGC from Static Solves... For uniform lines. Gives a lossless SPICE model
A circuit model of any network Export SPICE Model... Fits the S-parameters, and reports fit error and passivity
S-parameters Export ▾ › Touchstone Use in your circuit simulator

From a script:

result.write_rlgc_csv("line_rlgc.csv", length_m=0.00254)
rlgc = result.rlgc(length_m=0.00254)
print(rlgc.R.shape, rlgc.L.shape)    # (frequencies, conductors, conductors)

The S-parameter RLGC export assumes a uniform line. Launches and discontinuities get spread over the extracted values, so use it on sections that are actually uniform.

What's different from Q3D#

  • Full wave. TE10 includes radiation and distributed effects that a quasi-static solve leaves out, and L and C can vary with frequency.
  • No lumped-matrix workflow. TE10 doesn't offer Q3D's matrix reduction, such as joining nets in series or parallel, or separate DC and AC R/L matrix reports.
  • Ports matter. Short structures are sensitive to the port model because the port region is a large part of the total length.
  • Solve time. A full-wave solve of a small part usually takes longer than a quasi-static extraction.

Checking your results#

Short structures are sensitive to the port model, and full-wave and quasi-static solvers define R, L, G and C differently. If your work relies on absolute L or C values, compare a known structure from your own Q3D results before relying on TE10. See Validation for how TE10 Studio's solver changes are tested.

For EMI work#

Q3D models are often used to build parasitic models for emissions analysis. You can keep that circuit-based flow with an S-parameter or SPICE export, or solve the radiation directly. See EMI and radiated emissions.