Documentation

Docs / User guide

Surface roughness#

Rough copper loses more than smooth copper once the skin depth δ gets close to the size of the surface bumps: on PCB foils, from about 1 GHz up. TE10 Studio models this on finite-conductivity surfaces by multiplying the smooth surface impedance Zs(ω) by a roughness factor K(ω). The field inside the metal is still not meshed.

Where to set it#

  • Conductivity boundary (Boundaries › Assign Boundary › Conductivity (Lossy Metal)…): Surface roughness and the model's parameters. Applies to the faces of that boundary.
  • Metal material (material manager › Edit Material...): Surface Roughness. Applies to every conductor surface the mesher makes from solids of that material. The dialog previews the loss increase at 1, 10 and 40 GHz.
  • Scripts: prj.boundaries.conductivity(..., roughness="huray", radius="0.5um", surface_ratio=2.26) or prj.materials.set_roughness("copper", "groisse", rms="1um") (see Excitations and boundaries).

Models#

Model Parameters K(ω) Use
Huray (snowball) nodule radius a; surface ratio SR = N·4πa²/A_hex; A_matte/A_flat (default 1) A_matte/A_flat + Σ (3/2)·SR / (1 + (1 − j)·δ/(2a)) rough and very rough foils; keeps growing past 2×
Hammerstad–Jensen RMS roughness Δ 1 + (2/π)·atan(1.4·(Δ/δ)²) moderate roughness; at most 2×
Groisse RMS roughness Δ 1 + exp(−(δ/(2Δ))^1.6) moderate roughness; at most 2×

Huray uses Bracken's causal form (DesignCon 2012). Its loss is exactly the classic Huray ratio A_matte/A_flat + (3/2)·SR / (1 + δ/a + δ²/(2a²)), and the S-parameters stay causal for time-domain use. SR is the HFSS "Huray surface ratio": N nodules of radius a on a tile of area A_hex give SR = N·4πa²/A_hex. For example, a = 0.5 µm and N = 72 per 100 µm² give SR = 2.26.

K multiplies the whole impedance (resistance and internal inductance), in every solve type: driven (uniform, adaptive and interpolating sweeps), eigenmode, and the wave-port mode solve. With a Thickness set, K multiplies the finite-thickness impedance. Static solves ignore it.

Imported projects#

  • HFSS (.aedt, .aedtz, .a3dcomp): roughness on a Finite Conductivity boundary comes in exactly. The RMS roughness becomes Groisse, and the nodule radius and Hall-Huray surface ratio become Huray. HFSS uses the same formulas.
  • CST (.cst, .mtd): a lossy metal's surface roughness Rq comes in as Groisse with the same RMS, and the import log says so. CST solves Rq with its own Gradient model, which TE10 doesn't have. The two agree within about 5 % while the skin depth is larger than Rq (below about 4.4 GHz for Rq = 1 µm on copper). At higher frequencies CST's loss keeps rising past Groisse's 2× limit, so the imported model gives less loss there. Exporting a material to .mtd writes Hammerstad or Groisse roughness as CST's Rq. Huray has no CST material setting and is left out, with a warning.

Validation#

K(ω) was checked against Bracken's published curves and the closed-form Hammerstad/Groisse values, plus a 25 mm stripline from 1 to 40 GHz solved with smooth and rough copper. The extra insertion loss matches the analytic prediction IL_rough = IL_dielectric + K·IL_conductor.

Roughness needs the solver that comes with TE10. With another Palace build, a solve with roughness set stops with a message instead of running smooth.